Specification

  • VAT:
    23,00%
  • Weight:
    2kg
  • Manufacturer Code:
    SUBMK3F
  • Height:
    0 cm
  • Length:
    0 cm
  • Width:
    0 cm

Product Description

The Analox Sub Mk IIIF is a hyperbaric atmosphere monitoring system capable of measuring oxygen (O2), carbon dioxide (CO2), pressure (depth) temperature and relative humidity. It is ideal for use in hyperbaric chambers for HBOT or diving and for monitoring the atmosphere in Submarine Rescue Vehicles (SRV’s). The Sub Mk IIIF can also be configured as an O2 controller to automatically maintain oxygen concentrations to a preset level. The O2 controller would typically be used to maintain the chamber oxygen concentration or the oxygen concentration delivered from a bibs system on an SRV. The Sub Mk IIIF consists of a main control panel (operator console) and a number of remote sensor modules (REM’s). A large graphic display on the operator console shows the value of each measured parameter its units of measurement and alarm set points. Two audio/visual alarm channels are available for each measured parameter. The REM’s provide local, in chamber displays of the monitored parameters and repeat the audio visual alarm status

 

The Sub Mk IIIF is powered from a 9 to 24vDC supply, however an option to power from a mains AC is available. The operator console is designed to provide power to the REM’s. 5 cores through a penetrator would be required to enable this (2 power, 3 comm’s). Alternatively the REM’s could be powered locally. In its standard mode of operation the Sub Mk IIIF monitors the atmosphere via diffusion. This removes the need for pumps and their associated maintenance.

 

Sub Mk III F variations:

The Sub Mk IIIF is factory configurable to suit your individual application and requirements. The part numbers provided are indications of what we offer to suit these different applications.

 

Medical chambers

Basic installation might consist of an operator console with a REM1 and an optional REM2. Power is 24V as standard with external

 

Specifications

  • Range CO2: 0 to 20.00 mBar, 0 to 100.0 mBar
  • Range O2: 0 to 1500 mBar pO2, 0 to 3000 mBar pO2
  • Range Depth: 0.50 to 10.00 BarA, 0.50 to 60.00 BarA
  • Range Temperature: 0 to +50oC
  • Range Humidity: 0 to 100% RH
  • Operating Temp: 0 to +50oC
  • Power Options: 12 to 30 VDC 110 to 230VAC (option)
  • Outputs: 8 x 4 to 20mA channels
  • Voltage outputs (0 to 10V) (option)
  • Alarms: 1 alarm indicator for gas/environment alarms 1 fault indicator for communications, calibration and general system faults
  • Dimensions mm:
  • Operator Console 260x160x90
  • Sensor Modules 90x140x55
  • Data output: Real time data output on serial port for logging or display on external system

 

Sensor measurement techniques

 

Parameter

Technology

Location

Oxygen

Electrochemical

REM 1

Carbon dioxide

Infra-red absorption

REM 1

Pressure

Strain gauge

REM 1

Temperature

Platinum resistor

REM 2

Humidity

Capacitive

REM 2

 

 

 

 

 

Key Features

  • Illuminated display providing an easy to read screen
  • Can connect to 3 REM units allowing for a greater degree of flexibility
  • Audio and visual alarms ensuring you are notified of a potential issue

 

Power

A large graphic display on the operator console shows the value of each measured parameter, its units of measurement and alarm set points. Two audio/visual alarm channels are available for each measured parameter. The REM’s provide local, in chamber displays of the

monitored parameters and repeat the audio visual alarm status. The Sub Mk IIIF is powered from a 9 to 24vDC supply, however an option to power from a mains AC is available. The operator console is designed to provide power to the REM’s. 5 cores through a penetrator

would be required to enable this (2 power, 3 comm’s). Alternatively the REM’s could be powered locally. In its standard mode of operation the Sub Mk IIIF monitors the atmosphere via diffusion. This removes the need for pumps and their associated maintenance.

 

Technical Specification

  • Range CO2 - 0 to 20.00 mBar, 0 to 100.0 mBar
  • Range O2 - 0 to 1500 mBar pO2, 0 to 3000 mBar pO2
  • Range Depth - 0.50 to 10.00 BarA, 0.50 to 60.00 BarA
  • Range Temperature - 0 to +50oC
  • Range Humidity - 0 to 100% RH
  • Operating Temp - 0 to +50oC
  • Power Options - 12 to 30 VDC 110 to 230VAC (option)
  • Outputs - 8 x 4 to 20mA channels Voltage outputs (0 to 10V) (option)
  • Alarms - 1 alarm indicator for gas/environment alarms 1 fault indicator for communications, calibration and general system faults
  • Dimensions mm
  • Operator Console: 260x160x90
  • Sensor Modules: 90x140x55
  • Data output - Real time data output on serial port for logging or display on external system

 

CO2 monitoring & O2 monitoring with the Sub MKIIIF

The Sub MkIIIF provides vital gas readings of oxygen (O2), carbon dioxide (CO2), temperature, humidity and pressure allowing it to be used in both hyperbaric and hypobaric situations. The system consists of a central display unit and can be connected to a maximum of 3 remote sensors (REMs).

 

REMS are:

  • REM 1 measures oxygen (O2), carbon dioxide (CO2), and pressure
  • REM 2 measures temperature and humidity

 

Usage:

  • Diving
  • Submarine
  • Medical (HBOT) Hyperbaric Oxygen Therapy